Cochlear (Cochlear Implants)

Nucleus Nexa Implant, Nucleus 8 Nexa & Kanso 3 Nexa in Singapore

Cochlear™ Nucleus® Nexa™ System

The Cochlear™ Nucleus® Nexa™ System combines the new Nucleus Nexa Implant with the latest Nucleus 8 Nexa and Kanso 3 Nexa sound processors. It is described by Cochlear as the world’s first smart cochlear implant system, designed to deliver clearer sound, smaller and lighter processors, and future-ready connectivity for adults and children.

The future of hearing, delivered today

With the Nucleus Nexa System, Faith Hearing Singapore offers a cochlear implant solution that:

  • Responds to changing listening environments using advanced sound processing
  • Connects to a broad ecosystem of apps, accessories and remote care
  • Is future-ready, with internal implant memory and firmware designed for future upgrades*

*Availability of firmware updates and features depends on regulatory approvals and local release.

Watch: The Cochlear Nucleus Nexa System in action

Cochlear’s official video, “Cochlear Nucleus Nexa System – The world’s first smart cochlear implant hearing system”, introduces the idea of a cochlear implant that does not just work today, but is designed to keep advancing with you over time. It highlights:

  • The Nucleus Nexa Implant as a smart cochlear implant with built-in memory and firmware that can be upgraded in the future*
  • The Nucleus 8 Nexa and Kanso 3 Nexa sound processors as small, light options for everyday life
  • How the system is designed to help people hear more clearly in real-world situations like transport hubs, social gatherings and family time

Thinking about a cochlear implant for yourself or your child?
Book a consultation with our cochlear implant audiologist at Faith Hearing to see if the Nucleus Nexa System is suitable.

Nucleus® Nexa™ Implant – a smart cochlear implant

The Nucleus Nexa Implant is the “brains” of the Cochlear Nucleus Nexa System. It is described as the world’s first smart cochlear implant, with:

  • Internal memory that securely stores a patient’s MAPs (hearing program) on the implant itself
  • Upgradeable firmware, so future features may be added via a firmware update instead of additional surgery*
  • A design that supports dynamic power management, helping the system adapt its power use across the day while supporting all-day battery life with Nexa sound processors

This means your unique hearing settings can “travel” with you, even if you change to a new compatible sound processor in future.

*Not all firmware updates are available in all countries. Your audiologist will advise on approved updates in Singapore.

Cochlear™ Nucleus® Profile™ Plus (CI1000 Series) Electrode Arrays

Alongside the Nucleus Nexa Implant and Nexa sound processors, Cochlear offers the Nucleus Profile Plus (CI1000 Series) electrode arrays to suit different cochlear anatomies and surgical goals. These electrode arrays are designed to support hearing preservation where possible, and to position the electrode contacts optimally within the cochlea for hearing performance in patients with severe to profound hearing loss.

The choice of electrode array depends on individual cochlear anatomy, degree and configuration of hearing loss, and the surgeon’s preferred surgical technique (including hearing preservation goals). Your ENT surgeon and cochlear implant audiologist will discuss which Nucleus Profile Plus electrode option is most appropriate for you or your child.

The Latest Off-The-Ear

The Latest Implant Cochlear ™ Nucleus® Profile™ Plus (CI600 Series)

Cochlear offers a wide range of electrodes arrays* with the highest reliability rate on the market.

Cochlear’s latest generation of implants is the Nucleus Profile Plus Series. It features:

– World’s thinnest full-length perimodiolar electrode.

– Designed to best fit a cochlear’s natural shape and preserve the natural structures during surgery.

– Newly designed implant coil plates either side of a magnet pocket which contains a removable magnet cassette. This design allows for easy magnet removal and replacement for MRI.

Nucleus® 8 Nexa Sound Processor – behind-the-ear comfort and control

The Nucleus 8 Nexa Sound Processor is a behind-the-ear (BTE) processor for the Nucleus Nexa Implant. It is positioned as one of the smallest and lightest BTE cochlear implant sound processors, while still offering advanced sound processing and connectivity.

Key features of the Nucleus 8 Nexa sound processor

  • Small, light and discreet
    Designed to be very small and lightweight, helping adults and children wear it comfortably throughout the day, even with glasses or masks.
  • SmartSound® iQ 2 with SCAN 2
    The processor senses whether you are in quiet, noise, wind or music and automatically adjusts microphone directionality and noise reduction to help you hear speech more clearly in different environments.
  • ForwardFocus
    A clinician-enabled feature that can reduce noise coming from behind and around you, so you can focus on the person in front. It can be controlled in the Nucleus Smart App or automated, depending on your fitting.
  • Future-ready connectivity
    Direct streaming from compatible Apple and Android devices (calls, music, podcasts and learning apps), and a design that is ready for Bluetooth® LE Audio and Auracast™ broadcast audio as these technologies roll out.*
  • Water and dust resistance
    With compatible configurations, Nucleus 8 Nexa meets IP68 water and dust resistance ratings and can be used with Aqua+ for extra protection during water activities, according to Cochlear’s guidelines.

*Device compatibility, LE Audio and Auracast features depend on your specific smartphone, TV or accessory model and local approvals.

Kanso® 3 Nexa Sound Processor – off-the-ear, all-in-one design

If you prefer not to wear anything behind your ear, the Kanso 3 Nexa Sound Processor sits fully off-the-ear as a single compact processor on the head. It is described as one of the world’s smallest and lightest rechargeable off-the-ear cochlear implant sound processors.

Key features of the Kanso 3 Nexa sound processor

  • True off-the-ear option
    Good for people who wear glasses, masks or oxygen tubing, or for children who find a BTE processor hard to keep on.
  • Advanced Nexa hearing technology
    Includes the same core platform as Nucleus 8 Nexa with SmartSound iQ 2 with SCAN 2 and ForwardFocus, designed to help you hear speech more easily in everyday listening environments.
  • Built-in rechargeable battery
    The all-in-one design includes a rechargeable battery, aiming to support full-day use when charged according to manufacturer guidelines.
  • Connectivity and future-readiness
    Like Nucleus 8 Nexa, Kanso 3 Nexa supports direct streaming from compatible devices and is designed for Bluetooth LE Audio and Auracast broadcast audio in the future.*
  • Dust and water resistance
    Kanso 3 Nexa meets IP68 ratings in approved configurations and can be used with Aqua+ accessories for additional water protection.

*Features and availability depend on your implant type, connected devices, and regulatory approvals in Singapore.

Nucleus 8 Nexa vs Kanso 3 Nexa – quick comparison

Feature / Option Nucleus 8 Nexa – BTE Kanso 3 Nexa – Off-the-ear
Processor style Behind-the-ear with earhook All-in-one off-the-ear unit on the head
Size & weight Very small, light BTE processor Small, light rechargeable off-the-ear processor
Battery Changeable rechargeable batteries Built-in rechargeable battery
Main users Adults and children happy with behind-the-ear style Those preferring nothing on the ear (e.g. glasses wearers)
Hearing technology SmartSound iQ 2, SCAN 2, ForwardFocus Same Nexa platform and features
Connectivity Direct streaming, LE Audio & Auracast ready* Direct streaming, LE Audio & Auracast ready*
Water & dust resistance IP68 with approved configurations plus Aqua+ IP68 with approved configurations plus Aqua+
Book a cochlear implant consultation in Singapore
At Faith Hearing Singapore, our cochlear implant audiologist works closely with ENT surgeons to guide you through diagnosis, device selection, surgery planning and long-term follow-up for the Nucleus Nexa Implant, Nucleus 8 Nexa and Kanso 3 Nexa sound processors, as well as counselling on Nucleus Profile Plus (CI1000 Series) electrode arrays.

Clinic: #05-04 Orchard Medical Specialists Centre, Lucky Plaza, 304 Orchard Road, Singapore 238863